PROFIBUS FC RS 485 plug 180 PROFIBUS connector with FastConnect connection plug and axial cable outlet for Industry PC, SIMATIC OP, OLM, Transfer rate: 12 Mbit/s, terminating resistor with isolating function, plastic enclosure.
Specifications
Supply voltage AC 50 Hz (V) : 0 V to 0 V
Supply voltage AC 60 Hz (V) : 0 V to 0 V
Supply voltage DC (V) : 20.4 V to 28.8 V
Voltage type of supply voltage : DC
Input, current : No
Input, voltage : No
Input, resistor : No
Input, resistance thermometer : No
Input, thermocouple : No
Input signal, configurable : No
Output, current : Yes
Output, voltage : No
Output signal configurable : Yes
Analogue inputs configurable : No
Analogue outputs configurable : No
Number of HW-interfaces industrial Ethernet : 0
Number of interfaces PROFINET : 0
Number of HW-interfaces RS-232 : 0
Number of HW-interfaces RS-422 : 0
Number of HW-interfaces RS-485 : 0
Number of HW-interfaces serial TTY : 0
Number of HW-interfaces parallel : 0
Number of HW-interfaces Wireless : 0
Number of HW-interfaces USB : 0
Number of HW-interfaces other : 0
Supporting protocol for TCP/IP : No
Supporting protocol for PROFIBUS : No
Supporting protocol for CAN : No
Supporting protocol for INTERBUS : No
Supporting protocol for ASI : No
Supporting protocol for KNX : No
Supporting protocol for Modbus : No
Supporting protocol for Data-Highway : No
Supporting protocol for DeviceNet : No
Supporting protocol for SUCONET : No
Supporting protocol for LON : No
Supporting protocol for PROFINET IO : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for SERCOS : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for PROFIsafe : No
Supporting protocol for SafetyBUS p : No
Supporting protocol for other bus systems : No
Radio standard Bluetooth : No
Radio standard Wi-Fi 802.11 : No
Radio standard GPRS : No
Radio standard GSM : No
Radio standard UMTS : No
IO link master : No
Fieldbus connection over separate bus coupler possible : Yes
Rail mounting possible : Yes
Wall mounting/direct mounting : Yes
Front built-in possible : Yes
Rack-assembly possible : No
Suitable for safety functions : No
Appendant operation agent (Ex ia) : No
Appendant operation agent (Ex ib) : No
Explosion safety gas : None
Explosion safety dust : None
Width (mm) : 16
Height (mm) : 62
Depth (mm) : 34.5