Siemens digital i/o module, 24V DC voltage rating, 8 inputs – simatic 1763 series – 6es7131-6bf01-0ba0. Connect your PLC (programmable logic controller) to secondary devices with this digital i/o (input/output) module from siemens. The module processes data flow, keeping the system running smoothly and ensuring the successful transmission of commands from the PLC to machinery. To make it a versatile option, this device has 16 contact points with eight inputs and eight outputs that can all be used to connect to PLC channels, processors and power supplies.
Specifications
Supply voltage DC (V) : 19.2 V to 28.8 V
Voltage type of supply voltage : DC
Number of digital inputs : 8
Number of digital outputs : 0
Digital inputs configurable : Yes
Digital outputs configurable : No
Input current at signal 1 (mA) : 2.5
Permitted voltage at input (V) : -30 V to 30 V
Type of voltage (input voltage) : DC
Type of digital output : None
Permitted voltage at output (V) : 0 V to 0 V
Type of output voltage : DC
Number of HW-interfaces industrial Ethernet : 0
Number of interfaces PROFINET : 0
Number of HW-interfaces RS-232 : 0
Number of HW-interfaces RS-422 : 0
Number of HW-interfaces RS-485 : 0
Number of HW-interfaces serial TTY : 0
Number of HW-interfaces parallel : 0
Number of HW-interfaces Wireless : 0
Number of HW-interfaces USB : 0
Number of HW-interfaces other : 0
With optical interface : No
Supporting protocol for TCP/IP : No
Supporting protocol for PROFIBUS : No
Supporting protocol for CAN : No
Supporting protocol for INTERBUS : No
Supporting protocol for ASI : No
Supporting protocol for KNX : No
Supporting protocol for Modbus : No
Supporting protocol for Data-Highway : No
Supporting protocol for DeviceNet : No
Supporting protocol for SUCONET : No
Supporting protocol for LON : No
Supporting protocol for PROFINET IO : No
Supporting protocol for PROFINET CBA : No
Supporting protocol for SERCOS : No
Supporting protocol for Foundation Fieldbus : No
Supporting protocol for EtherNet/IP : No
Supporting protocol for AS-Interface Safety at Work : No
Supporting protocol for DeviceNet Safety : No
Supporting protocol for INTERBUS-Safety : No
Supporting protocol for PROFIsafe : No
Supporting protocol for SafetyBUS p : No
Supporting protocol for other bus systems : No
Radio standard Bluetooth : No
Radio standard Wi-Fi 802.11 : No
Radio standard GPRS : No
Radio standard GSM : No
Radio standard UMTS : No
IO link master : No
System accessory : Yes
Degree of protection (IP) : IP20
Time delay at signal exchange (ms) : 0.05 ms to 20 ms
Fieldbus connection over separate bus coupler possible : Yes
Rail mounting possible : Yes
Wall mounting/direct mounting : No
Front built-in possible : No
Rack-assembly possible : No
Suitable for safety functions : No
Performance level (EN ISO 13849-1) : None
Appendant operation agent (Ex ia) : No
Appendant operation agent (Ex ib) : No
Explosion safety gas : ATEX gas-ex-protection, Cat. 3G
Explosion safety dust : None
Width (mm) : 15
Height (mm) : 73
Depth (mm) : 58